The major activity has been the ongoing development and testing in vitro and acute in vivo of a unique small continuous flow Total Artificial Heart which has a single moving part. This effort is funded with a 4 year NIH grant and we are into the second year. Hemolysis testing has shown clinically acceptable low values and acute in vivo studies have confirmed the bench data. The latest pump iteration is fabricated from titanium components and will be used in a chronic in vivo study to assess biocompatibility.
With NIH funding, I lead a team developing and testing a unique artificial heart to completely replace a failing human heart. It has a single moving component and will fit essentially all adults and many teens. The pump is a continuation of work on rotary pumps – a major effort in my lab. Initial testing has shown good results, including very little damage to red blood cells. This "continuous flow" device now has an optional pulse provision.
| US Patent | Patent Title | Issue Date | First-Named Inventor |
|---|---|---|---|
| 7,189,260 | Ventricular Assist System Secondary Impeller | 3/13/2007 | Leonard A. Golding M.D. |
| 5,890,883 | Rotodynamic pump with non-circular hydrodynamic bearing journal | 4/6/1999 | Leonard A. Golding M.D. |
| 5,370,509 | Sealless rotodynamic pump with fluid bearing | 12/6/1994 | Leonard A. Golding M.D. |
| 5,324,177 | Sealless rotodynamic pump with radially offset rotor | 6/28/1994 | Leonard A. Golding M.D. |
| 5,145,333 | Fluid motor driven blood pump | 9/8/1992 | Leonard A. Golding M.D. |
Fukamachi K, Horvath DJ, Massiello AL, Fumoto H, Horai T, Rao S, Golding LAR. An innovative, sensorless, pulsatile, continuous flow total artificial heart: Device design and initial in vitro study. J Heart Lung Transplant 2010;29:13–20.
Fumoto H, Horvath DJ, Rao S, Massiello AL, Horai T, Takaseya T, Arakawa Y, Mielke N, Chen J-F, Dessoffy R, Fukamachi K, Golding LAR. In vivo acute performance of the Cleveland Clinic self-regulating continuous-flow total artificial heart. J Heart Lung Transplant 2010;29:21–26.
Saeed D, Massiello A, Shalli S, Fumoto H, Horai T, Anzai T, Golding LAR, Fukamachi K. Introduction of fixed-flow mode in the DexAide right ventricular assist device. J Heart Lung Transplant 2010;29:32–36.
Saeed D, Horvath DJ, Massiello AL, Ootaki Y, Benefit S, Golding LAR, Fukamachi K. Use of zirconia ceramic in the DexAide right ventricular assist device journal bearing. Artif Organs 2010;34:146-149.